Knowledge
Advancing Safety: Kingfa Medical Black Nitrile Gloves with Groundbreaking Technology
Dec. 03, 2024

As industrialization and safety standards rise, nitrile gloves have replaced latex gloves in various industries, becoming the preferred protective gear. Kingfa Medical, a leading innovator, has launched high-performance black nitrile gloves. These gloves excel in protection, comfort, durability, and operability. Here's an overview of Kingfa Medical's technological breakthroughs, advantages, and testing data.



Technical Breakthroughs: Innovative Design and Premium Materials

Kingfa Medical's black nitrile gloves, based on traditional nitrile gloves, have undergone substantial technological advancements to enhance their performance and adaptability:


High-Elasticity Formula Technology

Leveraging a proprietary high-elasticity formula, Kingfa Medical's black nitrile gloves offer unparalleled comfort and tactile sensitivity. This formula enhances stretch ability and conformability, ensuring a snug fit that is ideal for extended wear while mitigating hand fatigue.


Enhanced Abrasion Resistance

Through the refinement of nitrile rubber's molecular structure, the gloves exhibit significantly improved abrasion resistance. This makes them particularly suited for medical, industrial, and high-risk applications, where they can effectively withstand the rigors of daily operations and unexpected challenges.

 

Technical Advantages: Comprehensive Protection and Comfortable Experience

Kingfa Medical's black nitrile gloves boast numerous technical advantages, offering superior protection and comfort:

Exceptional Chemical Resistance

Kingfa Medical's black nitrile gloves provide excellent chemical protection against a wide range of common chemicals, including solvents, oils, acids, and bases. They are widely used in medical, laboratory, cleaning, and industrial settings.


Durability and High Elasticity

The high-abrasion-resistant formula ensures that the gloves do not easily tear during prolonged use, guaranteeing consistent protection. Additionally, the gloves' high-elasticity design enhances flexibility, providing a comfortable fit and precise operation.


Comfortable and Snug Fit Design

The seamless design of the gloves conforms to the shape of the hand, eliminating discomfort associated with traditional gloves and enhancing wearing comfort. The smooth and soft inner layer reduces friction, making the gloves easy to put on and take off.


Skin-Friendly and Hypoallergenic

Free from latex components, Kingfa Medical's black nitrile gloves are ideal for individuals with latex allergies. The finely treated inner surface avoids irritation common with traditional gloves, reducing the risk of allergies.


Rigorous Testing: Comprehensive Assurance of Product Quality

Kingfa Medical's black nitrile gloves undergo exhaustive testing protocols to ensure adherence to international safety standards and to deliver exceptional protective performance across various environments. Here are the key testing parameters and results:


Mechanical Property Testing

Tensile Strength: The tensile strength of Kingfa Medical's black nitrile gloves reaches 20 MPa, far exceeding the industry standard of 14 MPa. This high tensile strength ensures that the gloves are less likely to tear during high-intensity operations.

Elongation: The elongation test result for the gloves is 550%, indicating that they can maintain their shape under high tension without breaking. This ensures a comfortable fit and flexible operation.


Chemical Resistance Testing

Permeation Test: Kingfa Medical's black nitrile gloves excel in chemical permeation tests, effectively blocking the penetration of common chemicals such as alcohols, acids, and solvents, in compliance with industry standards.

Chemical Resistance: The gloves can withstand continuous contact with solvents for up to 480 minutes without permeation, ensuring reliability during long-term use.


Biocompatibility Testing (ISO 10993)

Skin Irritation Test: Kingfa Medical's black nitrile gloves have passed the ISO 10993 standard, showing no skin irritation, making them suitable for prolonged wear by users with sensitive skin.

Allergenicity Test: The gloves have passed allergenicity tests, causing no allergic reactions, ensuring user safety.


Microbial Protection Testing

Bacterial Penetration Test: The gloves have passed the bacterial penetration standard EN 374-5 test, effectively preventing the penetration of bacteria and viruses, ensuring safe use in medical and high-risk environments.


Ageing and High-Temperature Resistance Testing

High-Temperature Stability: The gloves have undergone accelerated ageing tests at 70°C for 72 hours, maintaining consistent performance without degradation, confirming their stability in high-temperature environments.


Food Contact Compliance Testing

Small Molecule Migration Testing: Under conditions of soaking in acid or alcohol at 40°C or 70°C for 2 hours, the migration of small molecules from the gloves is ≤10 mg/kg, meeting the stringent requirements for food contact materials.

 

Kingfa Medical's black nitrile gloves have become the preferred choice for users across various industries. Using a high-elasticity formula, advanced chemical protection technology, comfortable design, and rigorous quality testing, Kingfa Medical's black nitrile gloves excel in protective performance, comfort, and durability.

Whether in medical, industrial, laboratory, or other high-risk settings, Kingfa Medical's black nitrile gloves provide comprehensive and reliable protection, ensuring the safety and comfort of every user.


SOURCE:    http://www.medicalkingfa.com/solution-detail/id-639.html
CONTACT:   KINGFA MEDCIAL     Email: kingfamed@kingfa.com
Get a Quote
SUCCESS
You've successfully subscribed to our newsletter.
OK
Get A Quote Now